Home > HARDWARE > CONSTRUCTION HARDWARE > JOIST HANGERS & CONNECTORS
Choose a sub category:
JOIST HANGERS FRAMING ANGLES/ANCHORS MENDING PLATES
NAIL PLATES POST ANCHORS / CAPS FENCE BRACKETS
BRIDGING INSULATION SUPPORTS STRAPS
PLYWOOD CLIPS FOUNDATION ANCHORS BRICK/WALL TIES
MISC CONSTR HARDWARE
Sort By:
1 2 3 ... 6
USP Lumber JL26IF-TZ Standard Invert Flange Joist Hanger USP Lumber JL28IF-TZ Standard Invert Flange Joist Hanger USP Lumber JDS24 Double Shear Saddle Purlin Hanger
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Designed for quick installation of purlins between rafters, joists or trusses in post and beam structures. One-piece construction assures a consistent flush fit between purlin and joist or rafter. A reinforced "double lap" seat boosts the load capacity of this heavy-duty purlin hanger. Requires (4) 10d x 1-1/2" nails for header and (4) 10d" nails for each purlin. Features a 1-9/16" top fold; pending IAPMO-ES evaluation.
USP Lumber JUS210-2TZ Double Shear Slant Joint Hanger RH Tamlyn PC1532 Plywood Clip RH Tamlyn PCS716 Plywood Clip
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. With built-in spacer for use when support spacing exceeds the maximum length of an unsupported edge. Boxed. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed.
RH Tamlyn PCS12 Plywood Clip RH Tamlyn PCS1532 Plywood Clip USP Lumber SKH28R-TZ Skewed Left Joist Hanger
Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments.
USP Lumber SKH28L-TZ Skewed Left Joist Hanger Squeek No More 1011345 Screw Set RH Tamlyn PCS58 Plywood Clip
Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Specially scored waxed screws. Scored head breaks off at the same place every time. Carded. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed.
Acorn IHW16100 Insulation Support Wire 16 in L USP Lumber NA9-5MC Joist Hanger Nail Squeek No More 1010543 Floor Squeak Repair Kit
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. Structurally rated. For use with MiTek/USP Lumber Connectors' products. For additional information including withdrawal load and allowable shear per nail, please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Eliminate squeaks quickly and permanently. Can be applied to 2nd floors, hardwood floors, carpet, and stairs. Each kit contains: 1 - alignment and depth control fixture, 50 - specially scored waxed screws, 1 - special driver bit, 1 - complete instruction kit. Carded.
Acorn IHW24100 Insulation Support Wire 24 in L Deckmate 90166 Deck Bench Bracket with Bench Bracket USP Lumber RS20-R Coiled Strap
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. You determine the size. Connect with railing brackets with 2x4 and 2x6 lumber to easily add a bench to any size or shape deck. Gain increased seating area while using only 7" of deck space. Assembled unit stands 36"H for deck railing, seat is 17"H. Quick and easy to assemble using basic tools. Includes bench bracket, hardware and instructions. LUMBER NOT INCLUDED. Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
ANGLE 2X4IN TRIPLE ZINC 12GA  Acorn IHW16500 Insulation Support Wire 16 in L USP Lumber PA66R Post Anchor
Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes.
RH Tamlyn BT 22SP Corrugated Straight Brick Wall Tie RH Tamlyn BT22ZZSP Corrugated Scalloped Zig Zag Brick Wall Tie RH Tamlyn BT28ZZ5SP Corrugated Scalloped Zig Zag Brick Wall Tie
Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Boxed. Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8".
RH Tamlyn BT28500SP Corrugated Straight Brick Wall Tie ANGLE 2X6IN TRIPLE ZINC 12GA  USP Lumber JL24 Standard Joist Hanger
Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Boxed. Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber MP34 Framing Angle Deckmaster DMP125-10 Hidden Deck Bracket Kit Simpson Strong-Tie LSTA Light Duty Strap Tie
Use for joist/header installations. Does not have tabs. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505; ICBO 5736; DSA PA-076; Dade County, FL 01-0417.11; and  L.A. City RR25303 codes. 18 Gauge. System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies. For: 3/4" thick boards, composites less than 1-1/8", and any hollowcore composites. Consumer pack includes: 10 brackets, (120) 10 x 1" deck board screws, (110) 8 x 1" joist screws, and a pro bit tip. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
   
 
1 2 3 ... 6